電壓間距會影響 short risk、耐壓測試與安全距離。這個工具採用使用者自訂設計規則,適合做 layout 初期 clearance / creepage 快速估算,正式值仍需依產品適用標準確認。
Creepage and clearance spacing affects short risk, dielectric withstand testing and safety distance. This calculator uses a user-defined rule for early layout review before formal standard confirmation.
User-rule creepage and clearance spacing
公式: Recommended spacing = (minimum spacing + voltage / 100 x slope) x safety factor
Minimum spacing: baseline distance required by your internal rule.
Slope: additional spacing per 100 V.
Safety factor: multiplier for margin, contamination or process risk.
Design spacing: actual conductor-to-conductor spacing on the layout.
公式依據
Formula basis: editable internal-rule model for early clearance planning.
Reference: IEC 60664-1 defines the insulation-coordination framework used for clearance and creepage decisions in low-voltage equipment. https://webstore.iec.ch/en/publication/59671
Engineering note: this is not an official IEC, UL or IPC safety-spacing calculator; final clearance and creepage must follow the required product standard.
範例
With 50 V, 0.10 mm minimum, 0.10 mm per 100 V and 1.5x safety factor, recommended spacing is 0.225 mm.
輸入欄位
Working voltage
Design spacing
Minimum spacing
Voltage slope
Safety factor
結果輸出
Recommended spacing
Design margin
Pass / warning indication
工程注意事項
This is not a substitute for IEC, UL, IPC, customer or product-specific safety rules.
Creepage and clearance may differ depending on pollution degree, material group, coating and environment.
Use this planner to encode your internal rule or factory guidance before formal review.